煤礦機電制度匯編-

氧氣、乙炔氣瓶管理制度

氧氣、乙炔氣瓶的存放要有專用的廠房,并分別存放,不能跟其他材料混存。

2.氧氣、乙炔氣瓶在運輸過程中要分裝分運,不能混裝混運,瓶嘴要保證密封完好,不能有漏氣現象,防震圈完好無缺,出現漏氣防震圈缺損及時維修更換。

3.氣瓶在使用過程中,瓶與瓶之間要保持10米以上的距離,不能將氧氣、乙炔瓶放在一起開啟使用;在使用期間瓶周圍不能有其他易燃、易爆品存在。4.乙炔瓶在運輸及存放過程中要立放,不得平放。

5.氣瓶在裝卸過程中要輕拿輕放,避免瓶與瓶相互碰撞或與其他堅硬物發生碰撞,造成爆炸事故。

6.空瓶和充滿氣體的瓶要分開存放,并有明顯標志。

油脂庫管理制度

所有油脂入庫前必須按規定進行驗收,合格后方可入庫。所有油脂必須入庫,不準露天存放。

所有油脂必須分類碼放,并有醒目的標志牌,標明名稱、規格、型號。油脂庫必須在醒目處懸掛“油庫重地,嚴禁煙火”的標志。

油脂庫必須有專人管理,其消防器材必須按規定配齊并經常檢查,失交、損壞的及時更換。油脂庫周圍要保持清潔衛生,確保無雜草,無易燃物,無有礙交通,影響安全救護的設施、雜物,確保道路暢通。

嚴禁攜帶煙火進入油脂庫。

空油桶應選擇合適的固定地點,碼放整齊。

設備的前期管理制度

1.動力科根據設備需求,做好設備規劃,購置和驗收工作,加強前期管理.

第二篇:煤礦機電科制度

一、電氣試驗制度

1、井下防爆電氣設備,在入井前應由考試合格的防爆電氣設備檢查員,檢查其安全性能取得合格證后,方準入井。

2、新裝和大修后的電氣設備,在投入運行前必須進行絕緣電阻和吸收以及接地電阻的測定。

3、高壓電纜的泄漏和耐壓試驗及絕緣電阻測定每年一次。

4、避雷器絕緣電阻測定及工頻放電電壓測量試驗每年的三月十五日前完成。

5、變壓器和油浸電抗器的絕緣電阻和吸收比的測定,泄漏電流的測定,耐壓試驗每年試驗一次,絕緣油每二年至少進行一次交流耐壓試驗。

6、高壓開關柜斷路器的絕緣電阻和導電回路電阻的測定,每年測定一次。

7、地面防雷裝置實行定期檢測制度,每年檢測一次,地面樓房、建筑物防雷設施、避雷器的檢測工作,必須在每年的三月十五日前完成;對井下接地系統除執行日檢外,按規定要求每季進行一次搖測,不合格的必須處理。

8、保安工具,絕緣手套,絕緣膠靴及膠皮絕緣墊、絕緣臺、拉桿、高壓驗電筆放電棒,絕膠夾使用前,必須做相應的交流耐壓試驗,使用中的每半年進行一次試驗。

9、地面供電系統繼電保護裝置,全部項目的定期檢驗周期為一年。

10、井下高壓設備繼電器的保護裝置每季應根據短路電流和負荷變化進行一次整定值檢查,每年進行一次定期檢驗,當負荷變化隨時整定。

11、檢驗用的標準儀表,每年至少檢驗一次,盤用指示儀表每二年檢驗一次。

二、設備運行、維修、保養制度

1、設備運行制度:

⑴各類設備司機必須嚴格按照《操作技術規程》進行操作。

⑵凡本單位未使用過的設備,必須有主管技術員制定操作規程,經機電副總批準并組織人員培訓后方可交付使用。

⑶做到設備使用和維護相結合,誰使用誰維護,主要設備要實行包括司機在內的包機制,杜絕設備“三不管”的現象。

⑷設備使用要做到定人、定機、憑證操作,嚴格執行操作規程,崗位責任制、交接班制等。主要設備要做好各種運轉、檢查、試驗記錄。

⑸司機要經過培訓考試,合格后方可持證上崗。

⑹司機要做到熟悉本設備的主要性能,儀表指示值和操作規定。⑺設備嚴禁超負荷、超規范及帶病運轉,防止和杜絕跑、冒、滴、漏。⑻設備在使用中必須保持完好狀態,安全保護裝置齊全,靈敏可靠,防爆設備不失爆。設備開機前要做一次全面檢查。主要設備要執行司機巡回檢查制。

⑼設備在運行中發生事故,司機應根據當時的情況,采取緊急有效措施,防止事故進一步擴大,然后向上級匯報。

2、設備維修、保養制度

⑴所有設備都必須嚴格按照設備維修操作規程和完好標準進行使用與維護保養。

⑵貫徹設備使用與維護相結合的原則,設備誰使用,誰維護,實行包機制,嚴格執行崗位責任制和設備操作規程。

⑶各種設備司機必須經過培訓,達到設備操作的技術等級,經考試合格取證后方可操作。

⑷使用中的設備必須保持完好狀態,安全保護裝置齊全,動作可靠,防爆設備不失爆,并應定期檢查試驗,做好記錄。

⑸要嚴格執行日常維護保養和定期維護保養制度,確保設備經常保持整、潔,安全經濟運行。

⑹壓力容器應嚴格按照國家有關規定進行使用和管理,定期進行監測和預防性試驗。

⑺加強潤滑管理,建立并嚴格執行潤滑制度,做好換油記錄。⑻在用電高峰期,實行每天強制性兩小時檢修制度。

⑼大型固定設備嚴格執行巡回檢查和定期檢修制度,并認真填寫紀錄。

三、設備定期檢修制度

1、每月的六日規定為我礦停產大修日。

2、機電設備每日強制性檢修2小時,時間為:8:30~10:30。

3、主扇風機每季度由機電副總組織至少檢查一次反風設施,每年進行一次反風演習;主扇風機至少每月由機電部門檢查一次,兩臺風機必須保證一臺運行,一臺備用,備用風機必須能在10分鐘內開動。

4、鋼絲繩在懸掛前必須做試驗,升降人員的鋼絲繩以后每隔6個月進行一次試驗,保管超過一年的鋼絲繩,在懸掛前必須再進行一次試驗;升降人員的鋼絲繩在1個捻距內,斷絲面積與鋼絲總斷面積之比為5%必須更換。

5、提升絞車鋼絲繩每天由專人檢查一次,檢查時必須使用游標卡尺,分管技術員每周上崗檢查一次并簽名;每月必須由機電科長組織檢查一次。

6、主排水設備、水泵、管路、閘閥、排水用的配電設備和輸電線路必須經常檢查和維修;每年雨季前必須全面檢查檢修一次,并留有記錄,水倉應由礦組織每年清挖兩次,雨季前必須清理一次。

7、設備檢查完畢后,經檢查確無問題后進行運行試驗,在現場留人觀察不低于一小時,并做好記錄,然后方可投入正常運行。

四、機電干部上崗查崗制度

一、分管機電礦長每月上崗檢查三次(夜查活動不少于一次),檢查內容有:

1、各項制度的執行情況;

2、各種記錄填寫是否認真、正確;

3、干部上崗檢查制度執行情況;

4、工人執行制度和紀律的情況;

5、設備及機房衛生情況;

6、落實上崗發現的問題及處理情況;

7、填寫管理干部上崗登記薄。

二、機電副總、機電科長每月上崗檢查三次(夜查活動不少于一次),檢查內容有:

1、按分管礦長檢查的內容檢查;

2、按《煤礦安全規程》的規定,對電氣設備各部全面試驗檢查一遍,發現問題立即組織有關人員進行處理,處理后再次檢查試驗。

三、機電管理干部每隔不多于五天至少有一人上崗檢查一次(夜查活動不少于一次),檢查內容有:

1、按分管礦長檢查的內容(第3條除外)檢查;

2、按《煤礦安全規程》的規定,對電氣設備各部全面試驗檢查一遍,發現問題立即組織有關人員進行處理,處理后再次檢查試驗。

3、將上崗檢查結果填寫在記錄本內。

五、設備管理制度

1、設備組會同計劃科有關人員負責編制全礦機電設備購置計劃,除特殊情況下,任何人不得擅自購置設備。

2、構成固定資產的設備進貨時,會同供應、計劃、財務等部門有關人員共同進行驗收,認真檢查設備配套,技術性能備品配件,技術資料等是否符合要求,然后輸手續入賬入庫。

3、新、舊設備一律不準拆套,特殊情況下需要請示領導,設備組批準,調出調入設備一律經設備組辦理手續。

4、要認真抓好設備大修計劃落實情況,嚴格執行設備資金的管理,任何人不得挪用大修資金。

5、對于損壞嚴重造成報廢和服務年限已超,無修復使用價值的設備要向上級提出申請報廢,其它任何人不能將設備隨便提出報廢。

6、對于人為造成設備損壞或報廢,要給予追究責任,并按有關規定,給予適當的罰款。

7、設備組要建立設備發放、回收臺帳,更換或撤下來的設備原使用單位負責在三天內交回,并按要求存放到指定的地點,然后輸手續。(因工作面接續問題,有安裝單位和使用單位之間需要在使用現場辦理手續的設備,必須同設備組聯系辦理轉賬,其它任何人不準隨便調動)

8、設備組負責領取、發放現場檢查等工作,設備要分類編號,做到賬、卡、物、牌板四對口,數量清、狀態明。

9、設備組對不按時交回設備的單位,發出通知單,要求使用單位按時交回。

10、設備組要按時填寫有關各類報表,及時上報。

六、安全活動制度

為了更好的貫徹安全生產方針,切實抓好全礦安全質量標準,特制定本規定:

1、每周星期一作為各區隊的安全活動日,總結分析一周中存在的不安全隱患,對設備存在的問題,技術上的難點等進行分析討論;學習上級有關安全質量方面的文件。

2、每周星期三為技術業務學習時間,利用業余時間由技術員組織職工學習專業技術知識,并做好記錄。

3、每周星期四為政治學習時間,由各單位書記或其他干部帶領職工在業余時間學習國家方針政策、法律法規,傳達上級文件精神,做好職工思想工作。

4、值班干部要認真開好班前、班后會,并做好詳細記錄;根據“十種薄弱人物和十個薄弱時期”排查好薄弱人物;嚴禁酒后下井。

5、各分管人員要及時匯報各班組安全活動情況,對于重大技術難題或危及安全的隱患應由正職立即組織處理或分析研究采取措施。

6、各單位要建立健全安全活動記錄及各班組安全活動記錄,詳細記錄活動內容,參加人數及主持人。

七、事故分析追查制度

1、對所有發生的機電事故一定按規定進行詳細記錄,記清發生事故的時間、地點、事故原因、責任者以及造成的損失。

2、發生機電事故必須立即按規定向上級和有關部門回報,不得隱瞞。

3、認真堅持一事故一分析的制度,確定要把事故原因分析清楚,找出事故責任者,制訂出防范措施,以防止各類事故發生。

4、機電、運輸事故按影響時間、造成損失程度和性質分為一般事故、重大事故、特大事故和未遂事故。

5、發生一般機電運輸事故由礦組織機電科、安監處、調度室及有關部門進行分析處理。發生重、特大事故或性質較嚴重的未遂事故,由礦組織有關部門,集團公司參加分析,由礦提出處理意見報集團公司審批。

6、對發生事故的責任者,經分析后根據責任大小,對事故認識態度,按照礦及集團公司有關規定提出處理意見。

7、事故分析后,一般事故由礦發通報,重大以上事故由集團公司通報。

八、設備包機制度

1、各部門根據設備的性質,明確各班組責任范圍,保證每臺設備有專人維護保養。

2、各班組內實行定崗定人包機維修制,對所負責的設備按有關規定及巡回檢查圖表定期檢修,檢查負責設備的安全運轉。

3、包機人必須每天對各種保護,安全裝置進行一次試驗,發現問題及時處理,并認真作好原始記錄。

4、包機人應定期對儀器儀表進行校驗,保證指示準確、動作靈敏可靠,使各維修設備達到完好質量標準。

5、包機人對設備上存在不安全隱患及時處理。做到事事處理符合標準化。

九、防爆設備入井安裝、驗收制度

1、各種防爆設備,經防爆檢查員驗收合格,張貼防爆合格證后,方可下井使用,任何人不得私自利用職權或借口調非防爆設備入井。

2、設備安裝完畢,必須在防爆組驗收后,方能投入正常運行。

3、對井下使用的各種防爆電氣設備,防爆檢查組及使用單位要經常檢查其防爆狀況,使其各種指標保持在上限,使用單位要經常對防爆面清理涂油,以保證防爆面無銹蝕和隔爆性。

4、井下防爆設備無處不在,所以要做到以防爆組檢查為重點,群防群治,保證防爆率達到100%。

十、電纜管理制度

1、機電科負責全礦電纜的統一管理、計劃、領取、保管、維修和發放。根據全礦電纜的使用情況,及時編制全礦所需電纜的計劃,做到統籌兼顧,合理安排。

2、負責全礦各單位所用電纜的統一編號、領取及電纜的保管和發放,并及時修復利用,電纜的報廢有電纜組鑒定后供應科負責處理。達到帳、卡、物相符。

3、負責對各單位使用電纜情況的監督、檢查、驗收、考核工作。

4、各單位使用電纜,必須先提計劃,電管組審批后,到電纜組辦理領取手續,對電纜編號、建卡、入賬。

5、.各單位使用的電纜、信號電纜在上、下井及運輸途中不派專人護送的每次對單位主管領導及電工組長罰款50元,罰工資總額500元。

6、.耙裝機、局扇、水泵(潛水泵除外)、噴漿機、小絞車在上、下井運輸途中帶負荷電纜每發現一次,罰款200元。

7、用鐵絲吊掛電纜,每處罰款50元,缺電纜鉤一處罰款20元,電纜落地每米罰款20元,鋼鎧電纜鋼帶不合格,每處罰款100元。

8、各單位使用的電纜鉤丟失或轉讓、亂扔、亂放每個罰款60元,各單位的分管電纜區段,機電科每旬抽檢一次,發現一處吊掛不合格罰款50元,電纜衛生差,每米罰款30元。

9、現場使用的小型電器如發現電纜在喇叭口處截割,每處罰款100元,亂扔、亂放、私自拆配件和轉讓,每件罰款200元。

10、機電科安排任務通知卡下達后,必須及時完成臨時交辦任務,否則每次罰款200~500元,扣考核分2~5分。

十一、小型電器管理制度

1、各單位領取小電必須到機電科小電管理組辦理領取手續,由小電組進行發放。

2、單位之間調用小電者必須到小電組辦理交接手續,否則,每發現一次對雙方單位各罰款100元。

3、井下現場不得存放閑置小電,每發現一件對單位罰款50元,并限期3日內交到小電組,每超期升井一天加罰30元;地面電工車間內備用的小電,每一種不得超過2件,并有專用架子排放整齊,每超一件對單位罰款50元。

4、煤電鉆和電鉆綜保應按照礦規定的數量使用,超規定者按閑置論處。

5、新工作面安裝完畢,掘進迎頭及老工作面的回撤交接雙方必須到小電組辦理交接手續,填寫設備交接單,三日內必須辦完,無故拖延者每超一天罰款100元。

6、對機修廠修復的各種小電,由機電科下達月度檢修計劃,小電組對檢修好的小電進行檢查驗收后入庫;完不成計劃或檢修不合格,每臺件對機修廠罰款50元。

7、小型電器丟失按原值的2倍罰款;小型電器損壞每臺件罰款20元,造成報廢的按原值罰款;200A四通損壞每臺件罰款50元;煤電鉆零部件損壞罰款100元,煤電鉆燒壞每臺罰款300元;燒壞電鉆綜保本體每臺罰款200元。

十二、油脂管理制度

1、礦設專職油脂管理人員,其職責是:負責本礦申請油脂計劃,主要設備注油、換油、取樣、廢油回收及處理等。負責本單位油脂管理工的技術培訓。

2、各區隊設專職或兼職油脂管理員,其職責是負責本單位申請油脂計劃,主要設備注油、換油、取樣及廢油回收。機電科設專人管理油脂使用,對四大件等主要設備填寫潤滑卡片,存檔備查。

3、供應公司及各單位必須設專用油脂庫房,嚴禁露天存放。油脂庫結構要防火、防雨、防塵。存放乳化油的庫房冬季溫度不得低于攝氏10度,以防變質。

4、油脂在油脂庫中必須分類放置,桶上須明顯標記,注明油種、牌號、生產廠和進貨日期,防止過期。所有油桶必須清潔密封。

5、油抽子必須專用,用后不得亂放,防治灰塵污染。

6、油液使用前必須過濾、化驗合格,抗磨液壓油要有專用過濾器和油桶,嚴防臟物進入。過濾機、油桶、吸排油管定期清洗。

7、設備用油要符合規定,不準代用。不同油品、不同生產廠家和不同牌號的油不準混用。確需更換不同牌號的油品時,必須經礦機電副總批準,設備必須徹底清洗。抗磨液壓油若混用時,必須做混容試驗,合格后經機電副總批準方可使用。

8、油脂到貨時必須抽樣化驗,提出化驗報告,在發放時一并將化驗單轉到使用單位。新到油脂化驗不合格的,集團公司和礦油脂管理組負責與供方聯系退貨。

9、采煤機用抗磨液壓油、齒輪油等要按規定時間抽樣檢查和化驗,不合格時必須及時更換化驗合格的油。

10、乳化液的配制必須配備折射儀,定期檢驗乳化液濃度,配比濃度必須符合規定。

11、乳化液泵站周圍要保持清潔,無雜物、積水、浮煤,乳化液箱要加蓋,防止雜物掉入箱內。

12、設備換油時要全部回收交油脂管理組,并妥善保管,礦油脂管理組要組織舊油再生復用工作。

十三、配件管理制度

1、礦配件管理由礦供應科配件庫管理員負責。

2、配件管理員每年應將礦領導審批的計劃報集團公司進行統一匯編;申請“特種儲備”配件應備好圖紙資料。

3、關系到礦井安全,大型不易損關鍵件“特種儲備配件”由集團公司統一儲備,礦自儲的要隨年報、半年報,報集團公司統一編入特種儲備表。

4、要健全臺帳,帳物相符。嚴格執行配件驗收手續,對質量不好、數量和交期不符的要及時記錄和驗收報告。

5、管理員要對配件精心保養、防銹涂油、上蓋下墊、防止銹蝕損壞。

6、倉庫要保持清潔整齊,定量包裝,標簽要填全,懸掛整齊。

7、嚴格執行配件發放制度,按領料調配單發放,對不合手續的暫停發貨;配件帳目要整潔,技術數據要齊全準確,倉庫要設收、支、存資金動態牌板。

8、負責各種資料的統計和分析,并按上級要求及時上報各種報表。

9、報廢配件的條件是因主機淘汰、改型、變質和已損壞的、確實喪失使用價值的配件,每年申報一次報廢。

10、凡申請報廢的配件要履行報廢手續,必須經主管配件專業人員、工程技術人員、工人三結合小組鑒定,逐級審批。

十四、阻燃膠帶管理制度

1、新購置的阻燃輸送帶必須及時按要求取樣送檢測站檢測,并取回試驗報告單,保存不低于三年。

2、經檢驗不合格的皮帶嚴禁發放下井使用,并由訂購貨單位通知供貨單位退貨或索賠。

3、礦應對每年使用的阻燃輸送帶提前提出訂貨計劃,并落實資金。需要時按計劃到集團公司統一訂購部門領用,并檢查核對阻燃輸送帶是否有“四證”(安全標志準用證、檢驗合格證、出廠檢驗合格證、集團公司阻燃輸送帶檢驗合格證),否則拒絕領用。

4、阻燃輸送帶到礦后,應由礦供應部門和機電科指定專人負責阻燃輸 送帶的驗收、登記、建賬、建卡、統一發放和管理。

5、使用單位領用輸送帶時,要對新安或更換阻燃輸送帶的規格、型號、時間、地點、需用長度等進行建賬、建卡。

十五、雜散電流管理制度

在井下直流架線電機車鐵道運輸系統中,由于鋼軌與大地直接接觸,漏電率很大,如果再有鋼軌連接不善,就會使鋼軌中的電流有相當一部分被大地及其附近的鋼管分流,這部分電流成為雜散電流。雜散電流嚴重影響井下安全,因而必須對其采取防治措施。

1、按照《煤礦安全規程》第354條規定,由運搬區負責對電機

車運行的鋼軌軌道采取以下措施:

1)兩平行鋼軌之間,每隔50米應連接一根斷面不小于50mm2的銅線或其它具有等效電阻的導線。

2)線路上所有鋼軌接縫處必須用導線或采用軌縫焊接工藝加以

連接,連接后每個接縫處的電阻,不得大于下列規定。并且要經常檢查軌道接縫和軌道連接鋼筋,對開焊的接縫和鋼筋及時焊補。

15Kg/m鋼軌,0.00027Ω 18Kg/m鋼軌,0.00027Ω 22Kg/m鋼軌,0.00027Ω 24Kg/m鋼軌,0.00027Ω 30Kg/m鋼軌,0.00027Ω 33Kg/m鋼軌,0.00027Ω 38Kg/m鋼軌,0.00027Ω 43Kg/m鋼軌,0.00027Ω

2、不回電的軌道與架線電機車回電軌道之間,必須加以絕緣。第一絕緣點設在兩種軌道的連接處;第二絕緣點設在不回點軌道上,其與第一絕緣點之間的距離必須大于一列車的長度。對絕緣點必須經常維護,保持可靠絕緣。在與架線電機車線路相連通的軌道上有鋼絲繩跨接時,鋼絲繩不得與軌道相接觸。

3、按照《煤礦井下牽引網絡雜散電流防治技術暫行規定》設置變流所,縮短變流所的供電半徑。

對不執行以上規定的責任者,罰款50~200元,造成事故的 按礦有關安全文件規定執行。

十六、安全設施設備管理和檢修維護制度

第一章 總則

第一條 為貫徹“安全第一,預防為主”的方針,確保礦井生產過程中的人身和財產安全,減少設備事故的發生,加強設備現場危險作業環境及作業過程中安全防護設施的有效使用和管理,制定本制度。

第二條 本制度適應于全公司生產礦井全過程的安全設施管理和控制。第三條 礦井生產現場的安全設施必須由礦負責統籌規劃,制定響應的安全設施計劃并實施,建立相應的安全設施保證體系。

第四條 礦井作為安全設施管理的責任主體,應按國家有關規定,落實安全費用,并專款專用。

第二章 礦井設備安全設施的范圍

第五條 安全設施的內容、范圍:

⑴電氣設備的保護和接地必須符合《煤礦安全規程》第693條至第710條的規定進行檢查和試驗;

⑵礦井提升裝置必須按照《煤礦安全規程》第427條規定裝設下列安全保險裝置并符合要求:

①防止過卷裝置;②防止過速裝置;③過負荷和欠電壓保護裝置; ④限速裝置;⑤深度指示器失效保護裝置;⑥閘間隙保護裝置;⑦松繩保護裝置;⑧滿倉保護裝置;⑨減速功能保護裝置。

⑶空氣壓縮機必須符合《煤礦安全規程》第437條至第739條規定,設置下列保護裝置:

①超溫保護裝置;②設置壓力表和安全閥;③斷油斷水保護裝置。⑷主排水泵必須按照《煤礦安全規程》的規定設置水位報警裝置,相應配電系統符合電氣設備有關安全保護的規定,有條件的礦井應裝設泵房無人監控集控系統。

⑸主通風機必須按照《煤礦安全規程》的規定設置超溫保護裝置,機房內必須安設電流表、電壓表、水柱計等設施。

⑹井下運輸設備必須符合《煤礦安全規程》有關“平巷和傾斜井巷運輸”的相關規定設置安全保護裝置并保證靈活可靠。⑺礦井采掘設備的安全保護裝置必須按照《煤礦安全規程》的規定設置并確保靈敏可靠。

第六條 礦井設備的安全設施,必須按照《煤礦安全規程》和《肥礦集團公司機電管理規定》的標準進行定期檢查試驗。礦井主要提升裝置的安全保護,由維修工每天試驗一遍,司機每1小時巡檢一次,交接班時必須對內外過卷、腳踏開關等進行試驗,發現問題及時匯報,存在安全隱患時可以拒絕開車。對于鋼絲繩楔形連接裝置,每半個月進行一次抽檢,發現斷絲必須采取相應措施。每個月有礦機電負責人組織相關人員進行一次全面檢查,每年必須組織機電、地測等部門根據《煤礦安全規程》的規定全面檢查,寫出報告書,針對發現的問題,提出整改措施,限期進行解決。

第七條 對其余各崗點,必須根據崗點設備的性質和要求,定期對安全保護設施進行試驗,并對試驗結果進行記錄簽字。對于更換的安全設施備品備件,必須在檢修履歷簿中記錄清楚,檢修周期符合相關規定。

第三章 檢查試驗規定

第八條 礦井主要提升機的安全保護裝置必須由維修工每天檢查試驗一遍并將檢查試驗結果認真填寫清楚,發現問題立即處理、匯報,檢查處理結果必須簽字,實行責任負責制;每月礦井的機電負責人必須組織相關技術人員進行一次全面檢查,并簽字,做出結論性意見。正常使用的提升絞車,提升人員的每年進行技術測定,提升物料的每三年進行一次技術測定,檢查和測試結果必須寫成報告書,針對發現的缺陷,必須提出改進措施,并限期解決。

第九條 空氣壓縮機和主通風機、主排水泵等崗點的安全保護設施必須按照設備本身的要求和電氣設施的有關規定進行檢查、試驗,檢查、試驗結果必須在相關記錄上簽字備查。

第十條 各個崗點必須建立完善的管理干部上崗查崗制度,各級管理人員必須嚴格按照分工定期進行上崗、查崗以及定期組織人員全面檢查。上崗的內容和發現、解決的問題必須注明,如因外出等原因不能及時上崗的,則必須在外出前指定專人代其檢查,并說明原因。

第十一條 對于安全設施的檢修檢查,必須遵循“預防為主,以人為本”的原則,建立完善的定期檢修制度。檢修周期嚴格執行《肥礦集團公司機電設備管理規定》中的相關要求。檢修中的發現的問題、解決方法、更換配件、測量數據等必須在檢修履歷簿中填寫清楚,以便為以后的檢修留做參考。技 術負責人必須定期進行檢查,提出整改意見。

第十二條 各單位必須制定專門的技術資料管理制度,有專門的資料室和相關設備,設定專門的資料管理員,定員定編,所有資料必須作到清楚明了,存放科學,有專門的借閱制度。

十七、設備定期維修、缺陷管理制度

一、新裝和大修設備必須按照《煤礦電氣設備試驗規程》的規定,進行全面試驗并合格。

二、高壓電氣設備、電纜及各類表計,應按《煤礦電氣設備試驗規程》中規定的項目和周期進行檢查、試驗不合格不準送電。

三、6KV母線及設備,每年清掃兩次,所有設備及二次線均設專人,按規定做好定期檢查、檢修工作。

四、發現設備缺陷應及時設法消除,設備缺陷若暫時無法處理者,應及時向有關領導匯報,并制定專門的預防事故措施及必要的監視措施,增加巡回檢查的次數防止擴大。

五、對發現的運行或備用設備的缺陷,應認真填寫缺陷記錄,必要時在設備明顯部位上作明顯記號,以便設備停運后檢修人員能進行處理,填寫設備缺陷記錄要采用專業技術術語。

六、建立檢修、試驗及設備缺陷記錄簿,檢修人員按要求定期巡視設備,了解設備情況,并詳細記錄檢修,試驗和設備缺陷情況。

第三篇:煤礦機電標準化制度

目錄

一、電氣試驗制度 ······································································································ 1

二、設備運行、維護、保養制度 ········································································ 3

三、設備定期檢修制度 ···························································································· 5

四、機電干部上崗查崗制度 ·················································································· 6

五、設備管理制度 ······································································································ 7

六、安全活動制度 ······································································································ 16

七、事故分析追查制度 ···························································································· 17

八、設備包機制度 ······································································································ 18

九、防爆設備入井安裝、驗收制度 ··································································· 19

十、電纜管理制度 ······································································································ 20

十一、小型電器管理制度 ······················································································· 21

十二、雜散電流管理制度 ······················································································· 22

電氣試驗制度

1、電氣試驗前必須按規定辦理相關的工作票,同時要有經過簽批的安全技術措施。

2、電氣試驗員上班前不得喝酒,上班時不做與本職工作無關的事情,試驗時要嚴肅認真、集中精力,嚴格執行停、送電、驗電、放電等有關規章制度。

3、進行電氣試驗工作不得少于2人。

4、做井下電氣試驗時,電源線不應使用塑料線,應使用符合要求的電纜,只有當瓦斯濃度在1%以下時才準許進行電氣試驗;在礦井的掘進磧頭、可能發生突出的地區,要有專用局扇,并有瓦斯檢查員現場檢查瓦斯,各環境條件都符合要求后方可進行試驗。

5、對新型繼電器及繼電保護裝臵,必須有合法證件,否則不準投入使用和運行。

6、在控制盤和保護盤上工作時,必須將工作盤和兩側運行盤用布幔等加以明顯隔開。

7、在運行的二次回路上作業時,應穿低壓絕緣鞋或站在絕緣臺墊上,有專人監護,使用的工具用絕緣物包扎。電流互感器二次側不得開路,短路二次繞組必須使用不小于2.5平方毫米的短路片或短路銅線,且連接必須牢固可靠。禁止將電壓互感器二次側短路,嚴禁在帶電的電壓互感器上工作。

8、檢驗繼電保護和儀表的工作人員,不準進行任何倒閘操作,但在值班員許可后,可拉合開關。

設備運行、維護、保養制度

一、設備運行

1、值班人員要按時對運行中的設備按照巡回檢查順序或圖表進行巡回檢查,對設備異常狀況要做到及時發現,認真分析,正確處理,做好記錄,并向有關領導匯報。

2、值班人員進行巡視后,應將檢查情況及巡視時間做好記錄,發現不完好部位和隱患都應立即處理并將處理情況進行登記,不能處理的問題,應及時報告礦調度值班室和值班領導。

3、巡回檢查的內容:

(1)、容易松動的連接部位是否緊固;(2)、發熱的部位溫度是否正常;

(3)、潤滑部位油量是否適當,并及時補充注油;(4)、各儀表指示是否正常;(5)、運動部位有無振動及異常聲響;(6)、安全保護裝臵是否靈敏、可靠;(7)、其他部位狀態是否正常等。

二、設備維護、保養

1、設備維護、保養的主要內容:

(1)清掃、擦拭、檢查設備和注油,使設備和環境保持清潔整齊和潤滑良好;

(2)注意設備運轉情況,發現小故障及時排除,及時調整安全保護裝臵和緊固松動的機件,更換補充缺損零件、附件和工具;

設備定期檢修制度

一、為了保證設備正常運行,必須建立正常的檢查修理制度,一般包括日檢、周檢、月檢以及大中小修檢修制度,應嚴格執行。

二、日檢:主要由值班人員負責進行,檢查儀表上的數據,設備外觀的初略檢查等,作好記錄;周檢和月檢,應由值班人員和負責維修人員一起檢查,檢查接線狀況,螺絲是否松動,以及可能出現的問題。

三、小修:是指對機器設備進行的局部修理,以維修工人為主操作工人參加。

四、中修:對機器設備的某些主要部件進行解體檢修,對檢修完的設備必須按檢修標準檢驗且進行全面檢查。

五、大修:對機器設備進行全面修理,需要把機器設備全部解體,進行徹底修理。檢修好的設備必須按設備出廠或大修標準進行檢驗和全面檢查。

可根據設備實際使用條件,設備質量以及保養狀況等,由總工程師和相關管理人員決定合理安排設備的檢修周期,以便對設備進行定期檢修。

設備管理制度

一.總則

1、全礦機電設備由機電班統一管理,并實行分級負責制。根據實際需要配齊專職設備管理員,設備使用單位必須設兼職設備管理員,業務上隸屬機電班領導,工作情況由機電班進行定期考核。

2、全礦機電設備臺帳和總牌板、設備手冊和分類設備的主要技術資料檔案由機電班建立,各使用單位必須建立本單位設備臺帳。

3、全礦機電設備大修、改造、更新計劃的編制、匯總由機運科負責,報經礦長審批同意后,由機電班組織實施,因生產急需的計劃外項目,經礦辦公會批準。

4、有關機電設備管理方面的各種報表和資料,由機運科負責編制、匯總和上報。

二、設備的選型、購臵、開箱驗收制度

1、設備的選型:全礦各單位需要增臵設備時,應由使用單位會同設備管理部門提出增臵設備的技術性能、可靠性和維修性的要求,在技術負責人主持下,由機電、供銷、技術、財務、使用單位等部門對所需設備的型號和技術性能進行可行性分析。

分析論證應考慮以下幾個方面:(1)有較高的生產效率;(2)有較為可靠的質量;

(3)安全性能可靠,少污染,低噪音;(4)配套齊全、結構合理、靈活方便;

科組織有關安裝單位到安裝地點開現場會,介紹現場具體情況。

(2)為保證安裝工程按期按質完工,對安裝場所、峒室、巷道運輸條件必須首先進行檢查驗收,符合安裝施工要求的方可進行設備的安裝。

(3)安裝部門必須按《煤礦安全規程》、設計要求及煤礦安全質量標準進行安裝調試。

(4)安裝調試完畢,必須進行空載、半載和全負荷試運行,由生產技術科組織安裝、使用及有關單位進行驗收合格后方能交使用單位正式使用,并辦好正式移交生產手續。

(5)一般機電設備安裝調試、驗收合格移交生產后由機運科和使用單位及時建立圖牌板、卡片和各種管理制度。

四、設備更新改造、封存、啟封、調撥、報廢制度

(一)設備的更新改造:設備需要更新改造,應由機運科或生產技術科填寫申請書,并附更新改造方案報業主審批,批準后由機電班負責組織實施。

1、設備的更新原則是:用技術性能先進的設備更換技術性能落后又無法修復改造的老舊設備,凡符合下列情況之一者:

(1)設備老化、技術落后、耗能高、效率低或超過規定使用年限的老、舊、雜設備和國家有關部門規定淘汰的設備;

(2)大修理雖能恢復精度,但不如更新經濟的;

(3)嚴重污染環境,危害人身安全和健康,進行改造又不經濟的;(4)經過預測,大修理后技術性能仍不能滿足工藝要求和保證產品質量的;

1備;

4、因事故或其它災害,使設備遭受嚴重損壞,無修復價值的;

5、腐蝕過甚,無修復價值,或繼續使用易發生危險的設備。

五、設備的入庫、領用、交還、轉交

1、新購設備經開箱驗收、電氣設備經防爆檢查,通電試運后,方可入庫,檢修后的設備,憑驗收合格證入庫。

2、入庫的設備必須妥善保管,防止日曬雨淋,露天擺放的設備必須做到上蓋下墊,防止積水浸泡,無防腐處理的表面應涂抹防銹油,設備配件上架擺放。

3、設備庫必須設牌板、帳卡,做到帳、卡、物三對照,并及時根據設備變動情況進行調整。

4、設備領用,由領用單位管理人員持相關手續,設備管理人員依據批準手續發放設備;臨時增用設備,必須經礦、部門領導批準。

5、更換在用設備,必須有部門、礦領導的批準,并在七日內將損壞的設備交機電班檢修車間。

6、交還設備必須零部件齊全,經原使用、檢修單位、設備管理人員共同驗收后,辦理消帳手續。

7、采掘班組變動工作位臵,由礦組織交接雙方及設備管理人員現場清點后,辦理轉交手續,不經設備管理人員同意,各單位不得私自轉交設備。

六、特種和動能設備、引進設備管理制度

1、對特種設備和動能設備應設專人管理,操作人員必須經過嚴格培訓,經上級專業部門考核合格,持證上崗;專管人員必須做到“三

3清楚不放過;事故責任者沒有受到處理不放過;群眾沒有受到教育不放過;防范措施沒有落實不放過。

4、各采、掘、運班級及其它部門發生一般設備事故,應由跟班班長及管理及時向生產調度室匯報,并采取措施及時處理,迅速恢復生產。并要及時分析追查。

5、對發生的設備事故應認真做好統計,定期進行分析,不斷完善各種規章制度,或采取其它有效措施,使設備事故率不斷降低。

6、在每周的安全活動日和每月的安全工作會議上,向職工進行講述設備事故情況,發動職工分析事故原因,共同吸取教訓。

7、機運科應將每月機電設備事故情況及時整理,按規定的表式認真填寫月報表上報。

八、設備檢查與評比獎懲制度

1、礦成立以副礦長、技術人員、機電科長等組成的考評小組,定期或不定期對各單位設備管理工作進行檢查考核,對設備管理工作做出顯著成績的部門予以表彰或獎勵;對設備管理混亂、各項設備管理制度落實不好的部門給予批評或處罰。

2、各類獎罰由安監科和機電管理人員提出,經礦長審批后,交財務科實行獎罰。

3、連續三個月機電設備完好率達95%,電氣設備無失爆、標準化驗收達三級以上的部門,獎勵部門領導和機電維護安裝人員1000元。

4、機電設備完好率低于95%,標準化驗收低于四級標準的,處罰部門領導、機電維護人員和技術管理人員每人30元。

5、機電設備無“下井證”下井者,按每臺件2元處罰設備發放人

5行政處分。乳化液配比按礦有關規定執行。

16、井下閑臵的機電設備,以接到設備催送通知之日起2日內回收上井消帳,逾期不交者,按每臺每天10元罰款。

17、單臺更換下來的設備,責任班組應在當班回收上井到指定地點,并辦理消帳手續,否則按每臺件每天10元罰款。

18、未經批準擅自轉用機電設備的(含電纜、五小電器)按每臺件10元罰責任人。

19、凡回收上井的機電設備,其零部件不符合拆除前移交清單的數量時,按下列標準罰款:遺失件原值在100元(含100元)以下的,按原值的50%罰款;遺失件原值在500元(含500元)以下的,按原值的40%罰款;遺失件原值在1000元(含1000元)以下的,按原值的30%罰款;1000元以上的,由礦長領導確定,但不得少于500元。

20、設備應嚴格控制拆套使用,凡不經批準私自拆套的,按被拆部件原值的100%罰款。

21、蓄意破壞,造成設備損壞或影響生產,根據情況加倍處罰,造成嚴重后果的,提請司法機關依法追究刑事責任。

22、要愛護設備,一旦發生設備事故,應立即匯報礦調度室并采取相應的措施進行處理,盡快恢復生產,對造成設備事故隱瞞不報的,根據情況處以50~500元罰款。

23、徇私舞弊,違反國家和礦規定,任意處臵設備(包括五小電器、電纜)應給予設備原值2~5倍罰款。

24、對貫徹實施各項管理制度積極主動,并能搞好設備的維護保養,及時排查安全隱患,避免機電事故的人員由礦給予一次性嘉獎。

事故分析追查制度

1、提高全礦員工對事故的認識,切實端正態度,無論后果大小,都引起管理者的高度重視。

2、強化事故匯報制;凡發生一般機電事故都必須及時向機運科、井下跟班管理員和礦長匯報;凡發生較大的機電未遂事故及傷亡事故必須及時向礦長匯報。

3、凡發生重傷及死亡事故,礦領導到調度室親自指揮,按制定的救災措施進行挽救。

4、凡發生事故都必須進行事故追查,認真分析造成事故的原因,按照“四不放過”的原則進行追查處理。

5、通過對事故分析和追查,必須切實吸取事故教訓,并制定切實可行的安全防范措施。

9防爆設備入井安裝、驗收制度

1、防爆設備入井安裝前,應檢查其“產品合格證”、“防爆合格證”、“煤礦礦用產品安全標志”及安全性能。

2、入井使用前的防爆設備必須對隔爆接合面的粗糙度、間隙及接線引入裝臵等隔爆部位進行詳細檢查,隔爆性能必須符合防爆標準的要求,嚴禁失爆設備入井。

3、防爆設備裝車運輸時必須固定可靠,對小型貴重設備儀表,易損零部件應采取保護措施后,再進行搬運。

4、施工所用的起動用具,必須進行詳細檢查,確認完好無損后,方可使用,起重設備時,檢查支架棚子應安全牢固,正式起吊前應進行試吊,被吊物上嚴禁站人,吊起的重物下嚴禁有人。

5、安裝施工時必須嚴格執行停送電作業制度,從事高壓作業時,必須按停電、驗電、放電、封線、掛停電標志牌等順序工作。

6、安裝防爆設備時,要保護防爆面,不準用設備做工作臺,以免損壞設備,安裝完畢后,應符合防爆性能要求。

7、安裝完后的檢查、驗收

(1)、各類電氣設備的安裝必須符合設計要求,設備安裝垂直度,電纜的敷設、接線工藝應符合安裝質量標準。

(2)、電氣間隙、爬電距離、防爆間隙及接地裝臵應符合標準。(3)、安裝好防爆設備后必須按規定進行試運轉,經有關人員檢查驗收,試運轉正常后,才能交付使用單位使用,并作好記錄。

8、清理場地、工具、材料、儀表、儀器,試運轉正常后安裝人員才能離開現場。

小型電器管理制度

1、機運科必須設臵專人管理小型電器。

2、小型電器管理人員及其維修電工要經常對井下所使用的小型電器進行巡回檢查,特別是采掘工作面的小型電器,必須加強檢查,發現隱患和失爆必須及時處理或更換,使之符合小型電器完好標準。

3、小型電器完好標準如下:

(1)小型電器箱體內部清潔,螺栓緊固,箱體外表無銹蝕,無裂紋,標志齊全。

(2)小型電器隔爆面間隙與表面粗糙度應符合相關要求。(3)小型電器接線嘴無裂紋、損傷,接線柱不松動,不禿扣,接地裝臵、接線密封應符合規定。

(4)小型電器操作靈活,動作可靠,聲光訊號清晰。(5)小型電器工作電壓、電流符合銘牌規定,無過熱現象。(6)小型電器絕緣良好,660V不低于5MΩ;380V不低于2MΩ;127V不低于1MΩ。

4、檢修后的小型電器必須經防爆檢查員驗收合格后方可入井(入庫),并作好檢修記錄。

第四篇:煤礦機電安全隱患排查制度

機電安全隱患排查制度

為了貫徹“安全第一、預防為主”的方針,有效識別、排查和控制機電安全隱患,保證公司安全生產,根據有關法律、法規,特制定本制度。

一、采取多樣化機電專業檢查形式,針對性地做好機電一般性隱患排查。

公司機電專業檢查采取日常檢查為主,各項專業性檢查為輔的管理檢查形式。檢查形式:

1.在無公共檢查或交接行為的情況下,個人注重所轄范圍的日常業務管理。

2.機電專項檢查 ⑴膠帶機保護專項檢查

頻度每月一次,覆蓋全公司所有膠帶機,重點檢查膠帶機各項保護的設置與完好情況、防滅火設施等。

⑵井下低壓檢漏功效及接地極專項檢查

頻度每月一次,覆蓋全公司井下所有低壓饋電總開關、照明綜保、煤電鉆綜保和電氣設備的完好情況。

⑶絕緣用具使用情況專項檢查

頻度每兩月一次,覆蓋全公司所有變配電場所的絕緣手套、絕緣靴、接地棒和其它絕緣用具等。

⑷油脂專項檢查

頻度每月1次,覆蓋全公司所有機械變速設備及其運行場所(綜機設備除外)。

⑸防爆專項檢查

頻度每月一次,覆蓋全公司所有防爆機電設備、小型電器、線纜、通訊設備、照明用具和其它電氣設備設施等。

⑹鋼絲繩專項檢查

頻度每月一次,覆蓋全公司所有斜巷運輸絞車、副井提升機鋼絲繩的使用情況以及絞車場所鋼絲繩的備用情況等。

⑺井下接地電阻搖測專項檢查

頻度每季一次,采取實地抽檢的方式檢查。⑻其他專項檢查

對于日常檢查出的安全隱患首先進行分類,根據類別采取不同的措施進行消除和整改,對于重大機電隱患,納入機電重大隱患治理管理;對于一般性機電隱患,由機電專業組負責跟蹤治理。

二、機電重大隱患排查與治理管理

對重大機電隱患排查由機電副總工程師負責牽頭,機電部和機電工區技術人員參加,根據生產實際,對公司現存的機電重大隱患進行排查和識別;根據公司發展規劃,對公司將來的機電重大隱患進行預測,對排查和預測的機電重大隱患提出整改和防范措施,根據重大隱患等級報公司和煤業公司備案,對整改和防范措施實行蹤跟管理,由機電部詳細記錄重大機電隱患排查內容、整改措施和落實情況,并及時建立重大機電隱患管理臺帳詳細記錄重大隱患、整改措施、整改過程和結果,以便存檔備查。

簸箕掌煤業公司 二〇一一年八月七日

第五篇:中江煤礦機電例會制度

機 電 例 會 制 度

中江煤礦有限責任公司

中江煤礦機電例會制度

為了對每月機電工作進行總結和對下月機電工作任務提前做好規劃、處進各區隊、各部門機電人員的溝通與合作,集思廣益、提出創新性及科學性的工作方案,實現中江煤礦機電工作安全、有效管理,特制定本制度。

一、通知

1、時間:每月第一周周二下午3點;

2、地點:調度會議室;

3、議題:全礦當月機電所有事項及下月機電工作計劃安排;

4、主持人:機電礦長;

5、參加單位、范圍、人員:

礦生產部機電負責人、安監部機電負責人、供應部材料配件計劃員、調度室調度長、機電隊副隊長以上管理人員、運輸隊副隊長以上管理人員、通風隊技術員、采掘修各隊技術員、服務隊司爐班長(供暖期)參加。

(注:例會日期、時間如與礦其它工作安排相沖突,有變化時,礦調度室另行通知)

二、會議內容

1、傳達貫徹公司及本礦關于機電管理方面的有關精神。

2、下發各種管理制度、規范、標準、要求等,有針對性的學習相關的管理制度、系統圖紙、機電檢修標準和技術規范。

3、各單位總結上月主要機電工作;下月機電工作計劃;機電管理、機電設備管理中存在的問題;需要各區隊協助及礦協調解決的問題。

4、各單位對完成下月工作有困難的,集體協商解決辦法,并落實督辦責任人。

5、安監部通報上月安全檢查中機電工作存在的問題、處理及考核情況,安排本月機電工作重點。

6、調度室通報本礦及各單位上月機電事故影響生產情況,包括影響原因、時間及處罰情況,并進行分析,提出檢修重點、對各單位本月工作提出具體要求。

7、供應部通報本月設備、配件、材料計劃的采購情況及存在的問題。

8、生產部通報上月機電工作完成情況、機電運輸系統管理存在的問題、本月機電工作安排。

9、機電礦長總結工作及安排任務,提出工作要求及安排本月機電管理重點工作。

三、要求

1、會議遲到、早退罰責任人50元/次;未參加會議罰責任人200元/次;未按會議要求完成匯報工作罰責任人200元/次;未按時完成會議安排工作罰責任人200元/次;匯報工作不清、不實罰責任人200元/次。

2、各有關人員準時參加會議,有事必須向機電礦長請假,不得隨意遲到、缺會、早退,會議期間手機必須調至震動,否則罰50元/手機每響鈴一次。

3、調度室做好會議通知,生產部做好會議記錄、會議紀要、會議簽到等。

4、會議結束后生產部負責會議紀要整理,經機電礦長審核后下發并存檔備查。

5、機電隊、運輸隊提前準備好書面匯報材料報生產部。

6、各區隊、部室領導要認真落實會議安排的各項工作,嚴格檢查、考核、各項工作的落實情況。

中江煤礦 2017年12月26日

下載煤礦機電制度word格式文檔
下載煤礦機電制度.doc
將本文檔下載到自己電腦,方便修改和收藏,請勿使用迅雷等下載。
點此處下載文檔

文檔為doc格式


聲明:本文內容由互聯網用戶自發貢獻自行上傳,本網站不擁有所有權,未作人工編輯處理,也不承擔相關法律責任。如果您發現有涉嫌版權的內容,歡迎發送郵件至:645879355@qq.com 進行舉報,并提供相關證據,工作人員會在5個工作日內聯系你,一經查實,本站將立刻刪除涉嫌侵權內容。

相關范文推薦

    煤礦機電工作匯報制度[優秀范文5篇]

    工作匯報落實制度 為了進一步提高我隊干部職工的執行力,樹立工作、落實、匯報三點閉路循環意識,做到工作有布置、施工有落實、完成有匯報。特結合我隊工作實際制定如下工作匯......

    煤礦機電總結..

    機電專業上半年工作總結下半年工作打算 2013年上半年以來,機電專業認真貫徹落實上級一系列會議、安全指示精神,緊緊圍繞“精細管理,市場運作”的總體工作思路,堅持管理、裝備、......

    煤礦機電工作總結

    煤礦機電工作總結 煤礦機電工作總結2007-12-07 12:25:11第1文秘網第1公文網煤礦機電工作總結煤礦機電工作總結(2) 煤礦礦機電工作總結 各位領導,同志們,你們好! 時值陽春,萬物萌......

    煤礦機電總結

    2014年8月份機電專業工作總結 9月份機電專業工作安排 良莊礦業公司 二零一四年八月二十五日 一、八月份主要工作 1、突出抓好“雨季三防”工作,確保礦井安全渡汛。一是重點......

    煤礦機電設備管理

    設備包機制度…………………………………………… ……1 機電隊長抓機電制度………………………………… ……2 機電班長抓機電制度………………………………… ……2 配件......

    煤礦機電崗位責任制

    目錄 機電部長崗位責任制 ................................................................................................................ 3 機電副部長崗位責任制......

    煤礦機電管理制度

    雙岔河井機電管理制度 六 機電管理制度 6·1 電氣試驗制度 (一)閥型避雷器應按下表定期作試驗并符合標準要求。 1.絕緣電阻測定周期: (1)新裝和解體大修。 (2)變電所(站)避雷器每年雨......

    煤礦機電工作總結

    煤礦機電工作總結 時光荏苒,不知不覺中,十幾年的時光匆匆溜走。回顧以往,機電工作有收獲也有不足,我們緊緊圍繞安全生產方針,認真執行《煤礦安全規程》,以人為本,與時俱進,狠抓管理......

主站蜘蛛池模板: 精品无码国产一区二区三区麻豆| 成人亚洲精品久久久久软件| 国产又色又爽又黄的免费软件| 欧美日韩久久中文字幕| 美女裸体视频永久免费| 国产av亚洲精品久久久久李知恩| 国产精品嫩草99av在线| 国产成人精品三上悠亚| 欧美午夜刺激影院| 国产精品99久久久久久人| 免费1级做爰片在线观看爱| 18禁裸乳啪啪无遮裆网站| 99精品国产丝袜在线拍国语| 国产精品99| 亚洲一区二区三区自拍公司| 深夜福利小视频在线观看| 伦人伦xxx国产对白| 亚洲国产日韩a在线乱码| 一本一道中文字幕无码东京热| 狠狠噜天天噜日日噜| 亚洲日韩av无码一区二区三区人| 久久综合给合久久狠狠狠97色69| 内射极品少妇xxxxxhd| 久久精品成人欧美大片| 99久久九九免费观看| 亚洲r成人av久久人人爽| 亚洲中文无码av永久app| 成人午夜又粗又硬又长| 国产乱子乱人伦电影在线观看| 成人午夜精品无码区久久| 人妻无码一区二区三区免费| 无码国产玉足脚交极品播放| 精品久久人妻av中文字幕| 免费无遮挡无码h肉动漫在线观看| 国产精品无码一区二区在线观一| 国产精品久久久久久妇女6080| 精品无码国产一区二区三区av| 中文字幕av在线一二三区| 精品国产色情一区二区三区| 久久婷婷五月综合成人d啪| 欧美性黑人极品hd|